Testing
Onsite test labs help to speed custom and COTS products to market. Our ability to turn solutions quickly is supported by global test labs that evaluate both surge protectors and analyze networked equipment.
Hayden, Idaho Test Lab
- IEC 61000-4-5, IEC 61643-1 and IEEE/ANSI C62.41
- 8/20 µs Lightning Surge Generators: Keytek ECAT, Haefely Psurge 30, Velonex 587 and Custom “King Zap” up to 120 kA
- 10/350 µs and 10/1000 µs Waveforms Custom Long Wave Surge Generator for up to 100 kA
- RTCA DO-160 Aerospace and MIL-STD-461E CS116 Damped Sinusoid Drivers
- Solar 9354-1 Surge Generator
- Oscilloscope
- Tektronix TDS5104B 1 GHz and Lecroy WaveRunner 400 MHz
- 3000 MHz Pulse
- Network Analyzer
- Agilent 8753ES 3 GHz
- Fluke DSP-4300 Category 5
- Environmental Chamber
Shenzehn, China Test Lab
- 8/20 µs 200 kA Impulse Current Generator
- 8/20 µs 40 kA Impulse Current Generator
- 10/700 μs 5 kV Impulse Voltage Generator
- Environmental Test Equipment
Minden, Nevada Test Lab
- IEC 61000-4-5 8/20 μs
- Hafely P90.1 6 kV/3 kA
- Surge Generator 50 kA/100 kV
- Surge Generator 200 kA/100 kV
- GR-1089-CORE
- 10/1000 μs Surge Generator - 20 kV/2 kA
- 10/350 μs Surge Generator - 10 kV/8.3 kA
- 200/700 μs Surge Generator - 10 kV/3 kA